Monitor and control Dell PowerEdge servers from Home Assistant through their iDRAC, from iDRAC 6 to iDRAC 9:
- Server power state, with power on / graceful shutdown (switch and buttons), and forced power off / forced restart buttons for a hung server or one without an operating system to answer the shutdown request
- Power usage (W) and cumulative energy consumption (kWh, usable in the Energy dashboard)
- Temperatures and fan speeds
- Hardware health and per power supply health (problem sensors, e.g. to shut down when a PSU loses input)
No extra Python dependency: everything goes through the iDRAC's own HTTPS APIs.
| iDRAC | API used | Notes |
|---|---|---|
| iDRAC 9 | Redfish | Recent firmware (no /Power / /Thermal) handled through EnvironmentMetrics, ThermalSubsystem and Sensors. Energy from Redfish, or from the iDRAC web API when Redfish lacks it. |
| iDRAC 7 / 8 | Redfish, energy from the web GUI API | If Redfish is missing (old firmware) or disabled, the web GUI API is used for everything. |
| iDRAC 6 | Web GUI API (/data) |
iDRAC 6 has no Redfish. Old TLS (1.0) and small keys are accepted. |
The API is detected when the server is added and remembered.
Note on iDRAC 6 sessions: an iDRAC 6 only accepts a few simultaneous web sessions. The integration keeps a single one open and closes it when unloaded. If adding the server fails with "all its sessions are in use", log out of the iDRAC web interface (or wait for the idle sessions to expire) and try again.
Note
This integration requires HACS to be installed
- Open HACS
+ EXPLORE & DOWNLOAD REPOSITORIES- Find
iDRAC power monitorin this list DOWNLOAD THIS REPOSITORY WITH HACSDOWNLOAD- Restart Home Assistant (Settings > System > RESTART)
- Settings > Devices & services > Add integration >
iDRAC power monitor - Enter the IP address or hostname of the iDRAC, its username (
rootby default) and password (calvinby default).
Host, username and password can be changed later with Reconfigure on the integration entry; the polling interval with Configure.
scripts/idrac_probe.py queries an iDRAC with the integration's own code and prints what it reads (--raw adds the XML of the iDRAC 6 web API). Run it from a clone of this repository in an environment where Home Assistant is installed, and attach its output to issues about missing or wrong readings:
python scripts/idrac_probe.py 192.168.1.120 root calvin --raw
- iDRAC 6 support through the iDRAC web GUI API, without any new dependency (upstream #32, supersedes upstream PR #44 which needed IPMI)
- verified on real PowerEdge R510 and R710 (iDRAC6 firmware 2.92): power from the
systemLevelsensor shown on the iDRAC power page (pmReading/ipowerWatts1only cover part of the load), energy from the power tracking counter (ptsReadingc1, kWh), standby power from the one-minute average while the host is off
- verified on real PowerEdge R510 and R710 (iDRAC6 firmware 2.92): power from the
- Fan, temperature, power supply and health entities appear when the server is powered on, for servers added while off (the iDRAC publishes no sensors then)
- New entries are titled with the service tag, to tell identical servers apart
- iDRAC 7/8 without Redfish (old firmware, or Redfish disabled) now fall back to the same web API instead of failing
- iDRAC 9: fans and temperatures from
ThermalSubsystem/Sensorswhen/Thermalis missing or incomplete, power and energy fromEnvironmentMetrics(upstream #19, #36, based on upstream PR #38 with its odata path bug fixed and without the hardcoded model list) - "Server status" and the power switch now follow the host power state; they used the chassis health state and showed "running" on powered-off servers (upstream #19)
- New hardware health and per power supply problem sensors (upstream #25, #29)
- A powered-off iDRAC 6 reports its power supplies as "Unknown"; they read as unknown rather than as a problem
- Force power off and Force restart buttons, which cut the power or hard-reset the server without asking its operating system (Redfish
ForceOff/ForceRestart, iDRAC 6pwState0 / 3); power on, graceful shutdown and both forced actions verified on a real R710 (iDRAC6 2.92) - Host, username and password can be changed with Reconfigure, the polling interval with Configure; expired credentials trigger a re-authentication prompt (upstream #37)
- A pasted
https://…URL is accepted as host; a server can no longer be added twice - The HTTP session is released with
detach()instead of being closed, as it shares Home Assistant's connector - Energy: no more
sysmgmtlogin on every poll when Redfish already provides the counter; the energy sensor is only created when the iDRAC provides energy data - Rewritten on Home Assistant's
DataUpdateCoordinatorandaiohttp: no more blockingrequestscalls, 45 s request timeout instead of 300 s, entities become unavailable when the iDRAC is unreachable - Entity unique ids are unchanged: upgrading keeps entity ids and history (friendly names lose the duplicated model, e.g. "PowerEdge R720 Power usage")
- Add firmware version detection to disable legacy
/dataendpoint on iDRAC 9 firmware 7.x+ (fixes #41) - Prefer Redfish
PowerMetrics.EnergyConsumedKWhfor energy consumption over legacy endpoint - Fix error log spam on firmware that removed the
/data/loginendpoint - Fix potential
NameErrorin legacy endpoint logout when login fails
- Fix firmware version overwriting device info, causing platform setup failures on concurrent load
- Fix power sensor showing "unavailable" instead of 0W when server is in standby
- Fix binary status sensor showing "unavailable" instead of "off" when server is powered down
- Add
async_unload_entryto properly stop background polling and clean up on integration reload