Axiscope

Camera-assisted XY (and optional Z) tool alignment for multi-tool 3D printers running the Klipper Tool Changer plugin. No manual math — align each tool over the crosshair and Axiscope calculates the offset for you.


Axiscope UI


Table of Contents

Overview

Axiscope provides:

  • Manual XY calibration using live camera feedback
  • Quick T0 → Tn alignment, tool by tool
  • Automatic offset calculation — just align and capture, no math required
  • Optional automatic Z calibration via a fixed or portable endstop switch
  • Optional camera LED control (Ember Prototype CXC V2 camera)

Hardware

Camera

Option Details
DIY XY Nozzle Alignment Camera (3D printed parts) + OV9726 camera module + 4x 5V 3mm round white (6000-6500K) LEDs
Pre-assembled Ember Prototypes CXC — long USB cable, ready to mount, portable z endstop

The CXC V2 camera from Ember Prototypes has an onboard PWM-controlled LED that Axiscope can drive directly from a spare MCU PWM pin. See LED Control.

Z Calibration (Optional)

To use automatic Z calibration you need:

  • An endstop switch mounted at a known (or portable) position
  • The corresponding config added to printer.cfg — see Configuration

Installation

Prerequisites:

  • Klipper installed and running
  • Klipper Tool Changer
  • Moonraker configured
  • Camera set up in Crowsnest & Mainsail
  • SSH access to your printer

Install:

curl -sSL https://raw.githubusercontent.com/nic335/Axiscope/refs/heads/main/install.sh | bash

This script will:

  • Create a Python virtual environment
  • Install required dependencies
  • Set up the systemd service
  • Configure Moonraker integration

Start the service:

  1. Open Mainsail
  2. Go to Klipper → Service → Host Control and find axiscope
  3. Use the Start/Stop button

Service control

Configuration

Basic Setup

Add an [axiscope] section to printer.cfg. Only pin and the three zswitch_*_pos values are required (and only if you want automatic Z calibration):

[axiscope]
pin: !PG15                # Endstop pin
zswitch_x_pos: 226.71     # REQUIRED - X position of the endstop switch
zswitch_y_pos: -18.46     # REQUIRED - Y position of the endstop switch
zswitch_z_pos: 7.8        # REQUIRED - Z position + clearance of the endstop switch

lift_z: 1                 # OPTIONAL - Z lift before XY moves (default: 1)
move_speed: 60            # OPTIONAL - XY move speed, mm/s (default: 60)
z_move_speed: 10          # OPTIONAL - Z move speed, mm/s (default: 10)

led_pwm_pin: PB3               # OPTIONAL - PWM pin driving the camera LED
led_pwm_cycle_time: 0.010      # OPTIONAL - PWM cycle time, s (default: 0.010)
led_pwm_initial_value: 0       # OPTIONAL - Initial LED brightness 0.0-1.0 (default: 0)

start_gcode:
  {% set tools = printer.toolchanger.tool_numbers %}
  {% for tool in tools %}
      M104 T{tool} S150
  {% endfor %}
before_pickup_gcode: M118 pickup_gcode
after_pickup_gcode: M118 after_pickup_gcode
finish_gcode: M118 Calibration complete
  {% set tools = printer.toolchanger.tool_numbers %}
  {% for tool in tools %}
      M104 T{tool} S0
  {% endfor %}
  T0
Option Required Default Description
pin Yes* — Endstop pin used for Z calibration
zswitch_x_pos Yes* — X position of the endstop switch
zswitch_y_pos Yes* — Y position of the endstop switch
zswitch_z_pos Yes* — Z position + clearance of the endstop switch
lift_z No 1 Z lift (mm) before XY moves
move_speed No 60 XY move speed (mm/s)
z_move_speed No 10 Z move speed (mm/s)
led_pwm_pin No — MCU PWM pin driving the camera LED
led_pwm_cycle_time No 0.010 LED PWM cycle time (s)
led_pwm_initial_value No 0 Initial LED brightness (0.0-1.0)

*Only required if using automatic Z calibration.

Finding the Endstop Position

  1. Home the printer with T0 selected
  2. Jog the nozzle so it's centered directly over the endstop pin
  3. Note the current X, Y, Z position from your interface
  4. Use X and Y directly for zswitch_x_pos / zswitch_y_pos
  5. Add ~3mm clearance to Z for zswitch_z_pos (more if hotends vary in length)

Example: readings of X:226.71 Y:-18.46 Z:4.8 become:

zswitch_x_pos: 226.71
zswitch_y_pos: -18.46
zswitch_z_pos: 7.8  # 4.8 + 3mm clearance

Live Endstop Position Update

If you use a portable endstop (e.g. the CXC V2 camera), you don't need to manually edit zswitch_*_pos and restart Klipper every time you reposition it — update it live instead:

  1. Home the printer and jog the nozzle 1-2mm above the endstop switch
  2. In the Axiscope UI, click Set Endstop Position in the positioning panel
  3. Axiscope immediately updates its in-memory X/Y/Z endstop position to the toolhead's current position

Equivalent G-code:

AXISCOPE_SET_ENDSTOP_POSITION CURRENT=1                  # X, Y, Z = current toolhead position
AXISCOPE_SET_ENDSTOP_POSITION X=150.0                    # Only X
AXISCOPE_SET_ENDSTOP_POSITION X=150.0 Y=200.0 CURRENT=1  # X, Y explicit; Z from current position

Note: This updates the in-memory position for the current session only. To persist it across restarts, copy the reported values into zswitch_x_pos, zswitch_y_pos, and zswitch_z_pos in the [axiscope] section of printer.cfg.

LED Control (Ember Prototype V2 Camera)

If your camera has an onboard LED (e.g. Ember Prototype V2 / CXC), Axiscope can drive it via PWM directly from the printer's MCU:

  1. Wire the LED PWM input to a spare PWM-capable MCU pin
  2. Set led_pwm_pin in [axiscope] (see Basic Setup)
  3. Restart Klipper

Once configured, a brightness slider (light bulb icon) automatically appears in the Axiscope camera panel — drag it to set brightness 0-100%. It stays hidden if led_pwm_pin isn't set.

Control it directly from the console or a macro:

AXISCOPE_SET_LED VALUE=0.5   # 0.0 (off) to 1.0 (full brightness)

G-code Macro Options

Axiscope supports templated G-code macros with full Jinja support:

Macro Runs
start_gcode At the start of calibration
before_pickup_gcode Before each tool change
after_pickup_gcode After each tool change
finish_gcode After calibration completes

Remote Access (Hostname/Moonraker)

If you connect using a hostname (e.g. voron.local:3000), add *.local:* to moonraker.conf:

[authorization]
trusted_clients:
    192.168.0.0/16
    10.0.0.0/8
    127.0.0.0/8
    169.254.0.0/16
    172.16.0.0/12
    FE80::/10
    ::1/128
cors_domains:
    *.lan
    *.local
    *.local:*
    *://localhost
    *://localhost:*
    *://my.mainsail.xyz
    *://app.fluidd.xyz

Usage Guide

  1. Open http://<your-printer-ip>:3000
  2. Select the printer to calibrate (autofill support coming soon)
  3. Select the camera to use
  4. Align T0 perfectly to the crosshair, then Capture Position
  5. Switch to Tn, re-align to center, then press X and Y in the side navigator to compute the offset

T0 alignment
Capture and switch tool
Grab offset

Troubleshooting & FAQ

Camera doesn't show up in Axiscope

Make sure the camera is configured in both Crowsnest and Mainsail:

Camera only loads if plugged in before boot

Some cameras aren't auto-detected by Crowsnest if plugged in after boot. Restart the Crowsnest service instead of rebooting the whole printer.

Error: Duplicate chip name 'probe_multi_axis'

Duplicate chip name error

Cause: Both the toolchanger's calibrate_offsets.cfg and Axiscope are configured, and both use the probe_multi_axis chip name.

Fix:

  1. Remove/comment out the calibrate_offsets.cfg include in printer.cfg, or
  2. Only use one of the two calibration methods, not both

Only Axiscope should own the probe_multi_axis module.

Credits

Nic335 and N3MI-DG

License

MIT License — see LICENSE or the full text below.

MIT License text

Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:

The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.

THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.

About

A tool alignment interface for Klipper-based 3D printers designed to help with tool offset calibration in multi-tool setups.

Resources

Stars

113 stars

Watchers

6 watching

Forks

Releases

Packages

Used by

Contributors

Languages