A command-line tool that a GPU cloud runs on its own GPU nodes. It does two jobs:
- Readiness report. It scans the nodes and scores them against the 143 published ClusterMAX criteria, giving each row Meets, Partial, Gap or Unknown. You get category scores, an overall index and a ranked list of fixes, as JSON, a self-contained HTML page and Markdown. You can sign the JSON with Ed25519.
- Continuous health checks.
predge-ready healthis a fast check that exits with a status code. You run it as the SlurmHealthCheckProgram, from cron or from a systemd timer. It catches XID errors, ECC errors, throttling, overheating, missing GPUs, NVLink and InfiniBand links that are down, and optionally slow NCCL. It can drain or cordon the failing node itself, and it writes Prometheus metrics.
Independent readiness estimate. This is not a SemiAnalysis rating, and the project is not affiliated with or endorsed by SemiAnalysis. ClusterMAX is a SemiAnalysis trademark. A high score here does not predict a ClusterMAX medal.
pipx install git+https://github.com/predgeAI/cluster-readiness
# See a sample report without a GPU (recorded outputs from a healthy and a broken cluster)
predge-ready scan --demo broken
open predge-ready-report/report.html # xdg-open on Linux
# On a GPU node: scan it, state what was sold, sign the result
predge-ready scan --expect gpu=H100,count=8,ib=8 --sign
# Fast health check (exit 0 healthy, 1 warning, 2 failing, 3 could not check)
predge-ready health --expect gpu=H100,count=8You need Python 3.9 or newer. The tool uses only the standard library. If the cryptography package is installed it is used for signing; otherwise a built-in RFC 8032 implementation is used. Sample reports are in docs/examples/.
Every probe is read-only and needs no root. When a tool is missing or a file can't be read, the check reports Unknown with the reason instead of guessing.
| Area | What it looks at |
|---|---|
| GPU inventory | Model, count against lspci (to spot GPUs that have fallen off the bus), memory, driver and CUDA version, persistence mode, and the model and count you pass with --expect |
| GPU health | Clock-event (throttle) reasons, temperatures, volatile ECC errors, retired pages and row remapping, PCIe link width, NVLink link state, Fabric Manager, XID and SXID events from dmesg or journalctl -k |
| Fabric | ibstat port state, speed and link layer, ConnectX firmware, PKey table, HCA naming, /etc/nccl.conf (forced NCCL_PROTO/ALGO/MIN_NCHANNELS, GID index for RoCE), PCIe ACS (needs root) |
| GPUDirect | dma_buf path (open kernel module, kernel 5.12 or later) or nvidia_peermem, and GDRCopy |
| Software | NVIDIA Container Toolkit and driver against the published security minimums, Docker, Enroot/Pyxis, Apptainer, nvcc, HPC-X, NCCL, Lmod, DCGM |
| Scheduler | Slurm HealthCheckProgram, topology plugin, accounting, GPU GRES, PMIx. On Kubernetes: kubectl access, StorageClasses (RWX, default) and operators |
| Storage | Parallel filesystem (Lustre, Weka, GPFS, BeeGFS) versus NFS, and whether the shared mount responds |
| Monitoring | dcgm-exporter, node-exporter, ipmi_exporter, nv-hostengine, and automatic remediation (HealthCheckProgram, NHC, gpud, NPD, NVSentinel, the predge-ready timer) |
| Profiling | RmProfilingAdminOnly (ncu for non-root users), perf_event_paranoid, kptr_restrict |
--active also runs these tests where the tools exist. They load the GPUs, so use them on idle or drained nodes only:
dcgmi diag -r 3- the single-node nccl-tests
all_reduce_perf ib_write_bwloopback between two HCAs- an 8192³ bf16/fp16 GEMM through PyTorch
Each result is compared with a conservative floor for the GPU model.
predge-ready scan --hosts hosts.txt --expect gpu=H100,count=8,ib=8 # over SSH (BatchMode, your SSH config)
predge-ready scan --slurm gpu # every node sinfo lists in partition "gpu"
# or run on every node and merge:
srun -N 16 --ntasks-per-node=1 sh -c 'predge-ready scan --no-cmax --out /shared/pr --basename $(hostname -s) --format json'
predge-ready merge /shared/pr/*.json --out cluster-reportSSH mode installs nothing on the remote hosts. Each probe is a single read-only command. Across nodes the report also checks driver, GPU model and PKey consistency.
Each check is evidence for one or more criteria rows (run predge-ready criteria to list all 143). A row is:
- Meets when all of its evidence passes
- Gap when all of its evidence fails on every node
- Partial for anything mixed
- Unknown when nothing on a node can show it
Policy, commercial and provider-level rows (SOC 2, pricing, partnerships) are Unknown by design. You can record them with --answers answers.json (start from predge-ready answers-template). Those rows are marked self-attested, and they never override a measured result.
The readiness index counts Meets as 1 and Partial as 0.5 across all 143 rows. The report also shows the index over just the rows the scan could evidence.
If the cmax CLI (pipx install clustermax) is installed, scan runs cmax audit and merges its 74 audit checks into the same criteria rows. Turn this off with --no-cmax, or import an existing run with --cmax-results ~/.clustermax/audit/<run>. No cmax code is bundled. The minimum-version floors in src/predge_ready/data/minimums.json are a snapshot of the clustermax 0.3.0 minimum-versions.json (Apache-2.0). You can override them with --minimums.
predge-ready health --drain --resume --textfile /var/lib/node_exporter/textfile_collector/predge_ready.prom- Exit codes:
0healthy,1warning,2failing,3could not check. --drain: runsscontrol update nodename=<node> state=drain reason="predge-ready: XID 79, IB port down"on Slurm, orkubectl cordon <node>plus an annotation on Kubernetes. A node that someone else already drained is left alone.--resume: undrains the node once it is healthy again, but only ifpredge-readydrained it.--nccl: adds a quick NCCL all_reduce of about 10 seconds.
A run without --nccl takes a few seconds. Run every minute, it flags a bad node in about two minutes.
See docs/health-checks.md for the Slurm HealthCheckProgram setup, a systemd unit and timer, cron, and a Kubernetes DaemonSet outline. Ready-made files are in contrib/.
--sign creates a local Ed25519 key on first use (~/.config/predge-ready/ed25519.key, mode 0600) and embeds the public key and signature in the JSON. To check a report:
predge-ready verify report.json # integrity
predge-ready verify report.json --pubkey SHA256:... # integrity + who signed it
predge-ready keygen # print your fingerprint to publishThe signature covers the canonical JSON of the report without its signature field. It shows that a report hasn't been edited since the key holder produced it. It does not prove the hardware wasn't misrepresented to the tool.
Everything runs locally. The tool has no backend and sends nothing, and there is no telemetry and no network call. It only reads local state through standard tools, plus SSH to hosts you list. Reports are written to the directory you choose. Reports contain host names, GPU UUIDs and versions, so review them before you share them.
python -m unittest discover -s tests # or: pytest
python scripts/make_fixtures.py # regenerate the recorded node outputsThe fixtures in src/predge_ready/fixtures/ are synthetic recordings in the exact output formats of nvidia-smi, ibstat, dmesg, dcgmi, nccl-tests, ib_write_bw and scontrol. There are four nodes: two healthy HGX H100 nodes, and two broken ones:
- an H100 node with XID 79, ECC errors, throttling and an InfiniBand rail down
- an A40 node where H100 was expected
Apache-2.0; see LICENSE and NOTICE.
This project is not affiliated with, endorsed by or sponsored by SemiAnalysis. "ClusterMAX" is a trademark of SemiAnalysis and is used here only to refer to its publicly published criteria. The criteria IDs (SEC-1, REL-25, and so on) are Predge's own numbering. Scores are an independent estimate and are not a ClusterMAX rating.