Migration of a Blixt L1 control driver into the catalog. Depends on #89 (spec).

Driver: Solis S6 50-125 kW C&I hybrid — SvK control with configurable deactivation slew (activation stays immediate for FFR C-tier 0.70 s). FFR + FCR-D validated on a Blixt L1 test site.

Source: the Blixt L1 driver source, version 0.1.11.

Catalog-conformance changes (none to the control path — arm/setpoint/safe-revert/slew/self-heal untouched):

  • PROTOCOL + DRIVER header above the existing DRIVER_MANIFEST. Community tier; manifest control: true; control_enabled stays false until the control-v2 gates (lease, HIL, v2 entrypoints) are met.
  • Canonical W / inverter.W emit keys (Blixt L1 reads both spellings; headroom keys per spec: Blixt L1 headroom emit keys + inverter as reporting stream #89).
  • Poll reads go through a bounded per-block retry: after 3 misses in a row a block is left alone and re-probed periodically instead of costing a failed read every poll. Blocks come straight back when they answer (test_absent_register_settles).
  • No battery emit when nothing answered — the previous 0 W / 0 % on a failed read was a fabricated reading.
  • Portable write-result check (spec: Blixt L1 headroom emit keys + inverter as reporting stream #89): Blixt L1 raises on a refused write, FTW returns an error string; the driver now sees both.
  • driver_default_mode (the unprompted, timer-driven revert) stops reissuing a write the device has refused 3× in a row and logs once (test_refused_write_settles); the explicit deinit command always attempts the revert, and any successful write resets the counter.

make check green.

Safety

Control driver, v1 entrypoints. Safe revert = existing deinit_safe_revert (unchanged). No new write paths. control_enabled: false.

Package or promotion evidence

Control enabled: false. No package in this PR. Control activation is a separate change with default-mode, lease-expiry and HIL evidence.

David Mozart added 5 commits August 18, 2026 10:18
Blixt L1 battery/hybrid drivers report their AC stage on
host.emit("inverter", ...) and feed available_charge_W /
available_discharge_W (battery) and available_import_W /
available_export_W (inverter) into the arbitrator clamp. L1 reads
those keys by exact name with no lowercase fallback, and the profile
already names Blixt as the emit-key reference — but the four keys were
missing from emit_keys.canonical, and the emit-type tests rejected
"inverter" outright because it is not a DER type.

Add the keys to the profile, document that inverter is a stream (the
device is still declared as ders: [battery]), and let the structure /
manifest-consistency tests accept the stream without listing it in
ders. No driver changes; the emit-fields tests already derive their
allowed set from the profile.

Signed-off-by: David Mozart <david@sourceful-labs.com>
Blixt L1's host.write is FC16 with count=1 (Deye ignores FC06 on some
ranges) and exposes host.write_fc06 for true FC06; FTW's is FC06. The
two hosts also disagree on how a failed write is reported: FTW returns
an error string and never raises, Blixt returns true or raises. The
test harness follows FTW, so a Blixt-only driver that trusts pcall's ok
reads a mocked refusal as success. Document both, add write_fc06 to the
profile's modbus group, and give the portable check.

Signed-off-by: David Mozart <david@sourceful-labs.com>
test_signed_manifest_rejects_unsafe_runtime_fields mutated
payload.drivers[0] and relied on it being read-only. The catalog is
sorted by id, so the first control driver whose id sorts before
abb_meter (any id starting with a digit) made the mutations hit a
different, earlier check than the one under test. Select a read-only
modbus.read-only entry explicitly.

Signed-off-by: David Mozart <david@sourceful-labs.com>
konja-261-svk.lua + its manifest were staged by an over-broad git add;
they belong to #95, not here.

Signed-off-by: David Mozart <david@sourceful-labs.com>
… registry

Source: blixt-gateway l1/drivers/50-125k-svk-slew.lua @ 0.1.11 — newer than the registry's 0.1.10 (self-heal axis + undeclared-global fixes never uploaded).

Catalog conformance changes, none touching the control path:

- PROTOCOL + DRIVER header above the existing DRIVER_MANIFEST
  (sdm630/foxess pattern); community tier, control: true in the
  manifest, control_enabled stays false until the v2 gates pass.
- Emit canonical W / inverter.W keys (Blixt L1 reads both spellings).
- Poll reads go through a bounded per-block retry: after 3 misses in a
  row a block is left alone and re-probed periodically instead of
  costing a failed read every poll for the life of the session — the
  host counts each failed read against the poll. Blocks come straight
  back when they answer, so a bus hiccup cannot blind self-heal.
- No battery emit when nothing answered: the previous 0 W / 0 % on a
  failed read was a fabricated reading (the same trap the SoC hold
  already existed for).
- Portable write-result check (spec/host-api.md): Blixt L1 raises on a
  refused write, FTW returns an error string; the driver now sees both.
- driver_default_mode (the unprompted, timer-driven revert path) stops
  reissuing a write the device has refused 3 times in a row and logs
  once; the explicit deinit command always attempts the revert, and any
  successful write resets the counter.

Signed-off-by: David Mozart <david@sourceful-labs.com>
@davmoz
davmoz force-pushed the migrate/50-125k-svk-slew branch from d4b56e5 to 02ae119 Compare August 18, 2026 08:50
Base automatically changed from spec/blixt-l1-emit-keys to main August 19, 2026 07:12
claude added 2 commits August 19, 2026 07:17
…k-svk-slew

# Conflicts:
#	CHANGELOG.md
#	SUPPORT_STATUS.md
#	devices.yaml
#	index.yaml
#	support-status.json
@frahlg
frahlg merged commit 1383f6f into main Aug 19, 2026
6 checks passed
@frahlg
frahlg deleted the migrate/50-125k-svk-slew branch August 19, 2026 07:24
frahlg pushed a commit that referenced this pull request Aug 19, 2026
…xt L1 registry (#93)

Solis S6 50-125 kW C&I hybrid, AC-stage slew variant (writes 44284/85; PV shares the AC stage). Migrated byte-identical (newer, 0.2.3 vs registry's 0.2.2) plus the same catalog-conformance changes as #91/#92. Control path unchanged; control_enabled stays false, no package target exists yet.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment