Skip to content
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
36 changes: 18 additions & 18 deletions README.md
Original file line number Diff line number Diff line change
@@ -1,12 +1,12 @@
## Windows 1.8.2.1 maintenance release
## Windows 1.9.0.1 Station recorder release

Windows 1.8.2.1 packages the staff authorization, explicit database configuration and component metadata corrections. Its exact signed installed checks cover setup, the 1.8.1.1 upgrade, saved staff records, procurement/Contracts handoffs, backup/restore and uninstall retention. Unchanged module and 31-source/34-format import evidence remains attributed to the earlier build that produced it; this is not a new exhaustive test of every module or live provider.
Windows 1.9.0.1 integrates Station setup, camera and microphone selection, renewable operator sessions and verified large-recording transfers to Records.

Windows 1.8.2.1 has signed installed acceptance for fresh setup and an in-place upgrade from Windows 1.8.1.1. Before upgrading, back up city data and settings, close Townlight, run the signed MSI, and reopen it under the same Windows account with the existing `%LOCALAPPDATA%\CivicSuite` profile. Keep the prior installer and a restore path. Other upgrade paths are unverified. Station uses its separately configured service. The acceptance summary distinguishes new maintenance checks from reused workflow evidence.
Windows 1.9.0.1 has signed fresh-install acceptance, including Station recording, Records handoff and recovery. Set up Station during Townlight first run. Read the acceptance summary before upgrading.

[Release and downloads](https://github.com/townlight/townlight/releases/tag/townlight-windows-v1.8.2.1) · [Acceptance and limits](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.8.2.1/ACCEPTANCE-Windows-1.8.2.1.md).
[Release and downloads](https://github.com/townlight/townlight/releases/tag/townlight-windows-v1.9.0.1) · [Acceptance and limits](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.9.0.1/ACCEPTANCE-Windows-1.9.0.1.md).

Windows x64 Beta 1 · MSI 1.8.2.1
Windows x64 Beta 1 · MSI 1.9.0.1

Windows 1.8.1.1 adds shared meeting imports for 31 source families, with 34 supported source/format pairs. Installed Windows Sandbox checks exercised preview, save and durable readback using public captures and fixtures, plus the documented Townlight handoffs. These checks do not establish automatic discovery on every live portal or a complete retest of every module.

Expand Down Expand Up @@ -40,9 +40,9 @@ Windows 1.8.1.1 adds shared meeting imports for 31 source families, with 34 supp

[All 31 sources, formats and handoffs](https://townlight.github.io/manuals/meeting-imports.html) · [Installed acceptance](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.8.1.1/ACCEPTANCE-Windows-1.8.1.1.md).

Windows 1.8.2.1 has signed installed acceptance for fresh setup and an in-place upgrade from Windows 1.8.1.1. Before upgrading, back up city data and settings, close Townlight, run the signed MSI, and reopen it under the same Windows account with the existing `%LOCALAPPDATA%\CivicSuite` profile. Keep the prior installer and a restore path. Other upgrade paths are unverified. Station uses its separately configured service. The acceptance summary distinguishes new maintenance checks from reused workflow evidence.
Windows 1.9.0.1 has signed fresh-install acceptance, including Station recording, Records handoff and recovery. Set up Station during Townlight first run. Read the acceptance summary before upgrading.

Windows 1.8.2.1 contains Townlight Runtime 0.3.2 and Meetings 1.0.6. Its current component sources and installed evidence are identified in the maintenance acceptance summary.
Windows 1.9.0.1 contains Station 0.4.0, Records 1.8.0.dev4, Townlight Runtime 0.3.2 and Meetings 1.0.6. Its current component sources and installed evidence are identified in the maintenance acceptance summary.


**Townlight Beta 1** · Naming candidate documentation edition 2 November 2026
Expand Down Expand Up @@ -80,31 +80,31 @@ Staff should begin with First run and Daily workflow. Administrators should also
| Identity | Value |
|----|----|
| Documentation | Townlight Beta 1 naming, Access and Notice candidate |
| Windows MSI version | 1.8.2.1 |
| Windows MSI version | 1.9.0.1 |
| Product component | townlight-core 1.3.0.dev2 |
| Principal import package | townlight_core |
| Native desktop source version | 1.8.2-1 |
| Candidate hashes | [SHA-256 checksums](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.8.2.1/SHA256SUMS-Windows-1.8.2.1.txt) and [Windows acceptance summary](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.8.2.1/ACCEPTANCE-Windows-1.8.2.1.md) |
| Native desktop source version | 1.9.0-1 |
| Candidate hashes | [SHA-256 checksums](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.9.0.1/SHA256SUMS-Windows-1.9.0.1.txt) and [Windows acceptance summary](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.9.0.1/ACCEPTANCE-Windows-1.9.0.1.md) |
| Current owned software license | AGPL-3.0-only |
| Acceptance composition | Windows 1.8.2.1: fresh-install and 1.8.1.1 upgrade acceptance. Select the full profile. Station uses separate configuration. |
| Acceptance composition | Windows 1.9.0.1: signed fresh-install acceptance. Station setup is integrated. |

Windows 1.8.2.1 has signed installed acceptance for fresh setup and an in-place upgrade from Windows 1.8.1.1. Before upgrading, back up city data and settings, close Townlight, run the signed MSI, and reopen it under the same Windows account with the existing `%LOCALAPPDATA%\CivicSuite` profile. Keep the prior installer and a restore path. Other upgrade paths are unverified. Station uses its separately configured service. The acceptance summary distinguishes new maintenance checks from reused workflow evidence.
Windows 1.9.0.1 has signed fresh-install acceptance, including Station recording, Records handoff and recovery. Set up Station during Townlight first run. Read the acceptance summary before upgrading.

## First run

Windows 1.8.2.1 has signed installed acceptance for fresh setup and an in-place upgrade from Windows 1.8.1.1. Before upgrading, back up city data and settings, close Townlight, run the signed MSI, and reopen it under the same Windows account with the existing `%LOCALAPPDATA%\CivicSuite` profile. Keep the prior installer and a restore path. Other upgrade paths are unverified. Station uses its separately configured service. The acceptance summary distinguishes new maintenance checks from reused workflow evidence.
Windows 1.9.0.1 has signed fresh-install acceptance, including Station recording, Records handoff and recovery. Set up Station during Townlight first run. Read the acceptance summary before upgrading.

### Fresh installation

Run the signed Windows 1.8.2.1 MSI and use an empty database and a new Townlight profile for first run.
Run the signed Windows 1.9.0.1 MSI and use an empty database and a new Townlight profile for first run.

1. Download the signed MSI, matching source companion and checksums from the [public Windows release](https://github.com/townlight/townlight/releases/tag/townlight-windows-v1.8.1.1).
2. Verify the MSI hash and Authenticode publisher before installation. See the [Windows acceptance summary](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.8.2.1/ACCEPTANCE-Windows-1.8.2.1.md) for the tested setup.
2. Verify the MSI hash and Authenticode publisher before installation. See the [Windows acceptance summary](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.9.0.1/ACCEPTANCE-Windows-1.9.0.1.md) for the tested setup.
3. Launch Townlight under the intended named Windows account. Choose the storage folders. Select **Townlight Inspections candidate** (`inspections-preview`) for the bounded desktop composition, including Access and Notice. A narrower default selection will not expose all workspaces.
4. Enter the city profile, time zone and contacts. Create the first named local administrator, sign in and choose protected backup storage. **Continue without local AI** is valid for the deterministic workflows.
5. Run Health Check and wait for readiness. Open Townlight. In System Health select **Finish Records Migration** to activate the canonical Python/PostgreSQL runtime. Do not fabricate migration receipts or seed accounts.
6. Create named staff through Settings. Import authorized sources using each product’s source library. All examples in this package are synthetic; they are not municipal authority.
7. Provision Station separately if it is part of the beta exercise. Selecting the desktop composition does not start or configure Station. Configure vision explicitly only if automatic photo drafting is selected.
7. Set up Station during first run with the full profile or with Meetings and Records selected. On an existing installation, open Settings → Modules → Townlight Station → Set up meeting recording. Configure vision explicitly only if automatic photo drafting is selected.

## Daily workflow

Expand Down Expand Up @@ -254,7 +254,7 @@ Source contracts: `townlight_core/catalog/__init__.py`, `townlight_core/exemptio

### Runtime and storage

The Windows 1.8.2.1 package has signed fresh-install and 1.8.1.1 upgrade acceptance. Its native shell uses **Rust 2021, Tauri 2 and Microsoft WebView2**; browser assets are JavaScript built with **Vite 8.1.6**. This describes the native desktop frontend; Station has a separate React operator, specified below or in its product manual. Canonical business workflows use bundled **CPython 3.13.5, FastAPI, Pydantic, SQLAlchemy and Alembic**, with **PostgreSQL 17 / PostGIS** and managed original files. Bundled dependency versions are recorded with the release evidence. Package minimum Python requirements can differ from the bundled executable; the metadata reference preserves both. No stack rewrite is implied by the beta label.
The Windows 1.9.0.1 package has signed fresh-install and Station recorder acceptance. Its native shell uses **Rust 2021, Tauri 2 and Microsoft WebView2**; browser assets are JavaScript built with **Vite 8.1.6**. This describes the native desktop frontend; Station has a separate React operator, specified below or in its product manual. Canonical business workflows use bundled **CPython 3.13.5, FastAPI, Pydantic, SQLAlchemy and Alembic**, with **PostgreSQL 17 / PostGIS** and managed original files. Bundled dependency versions are recorded with the release evidence. Package minimum Python requirements can differ from the bundled executable; the metadata reference preserves both. No stack rewrite is implied by the beta label.

The native transport is fixed to loopback `127.0.0.1:15480`; PostgreSQL uses the configured local runtime port (default `15432`). Optional local model service defaults to `127.0.0.1:15434`. Those are deployment defaults, not internet endpoints. The runtime has health, module and readiness endpoints; readiness is stronger than process existence. The task queue is the existing local Core task infrastructure, not an assertion that a separate Redis service is required for this desktop composition.

Expand Down Expand Up @@ -424,7 +424,7 @@ Staff verify the jurisdiction, source currency, permissions, citations and propo

### Beta operation and recovery

Windows 1.8.0.1 was tested for fresh installation and in-place upgrade from 1.7.2.1. Upgrade paths from versions older than 1.7.2.1 are unverified. Station uses its separately configured service. Keep backups and original evidence. Test your physical equipment and network and service configuration before relying on them. See the [acceptance summary](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.8.0.1/ACCEPTANCE-Windows-1.8.0.1.md) for the tested paths.
Windows 1.8.0.1 was tested for fresh installation and in-place upgrade from 1.7.2.1. Upgrade paths from versions older than 1.7.2.1 are unverified. Station is configured during Townlight first run. Keep backups and original evidence. Test your physical equipment and network and service configuration before relying on them. See the [acceptance summary](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.8.0.1/ACCEPTANCE-Windows-1.8.0.1.md) for the tested paths.

### Warranty and liability

Expand Down
Loading